Download
this information (PDF File)
(Right-Click / Save As)
|
AccuScan
2-Probe Inspection System With ERO
|
|
Analog
/ Digital Converter
|
| A/D
Conversion |
16-bit |
|
Mechanical
Runout Probe
|
|
Other
probes available: Pencil LVDT or Half Bridge,
Laser, Capacitance. Measuring ranges up to +/-
0.5in
|
| Standard
Probe Type |
TESA
Auto reversing bi-directional lever probe** |
| Sampling
Resolution |
0.76
µ in |
0.02
µ m |
| Cable
length |
7ft
(14 ft with extension) |
2m
(4 m with extension) |
| +/-2s
Repeatability*** |
4
µ in |
0.101
µ m |
| Accuracy*** |
+/-
6.3 µ in |
+/-
0.16 µ m |
| Measurement
Force |
0.36
oz |
10
grams |
| Spindle
Pretravel |
0.002
in |
0.05
mm |
| Measuring
Range |
+/-
0.012 in |
+/-
0.3 mm |
| Overtravel |
0.002
in |
0.05
mm |
| Contact
Point Diameter |
0.079
in |
2
mm |
|
Electrical
Runout Probe (ERO)
|
| Probe
Type |
Bently-Nevada
Non-Contact Eddy Current Probe |
| Sampling
Resolution |
1.2
µ in |
0.03
µ m |
| Cable
length |
3.25, 16.25, or 29.25 ft |
1, 5, or 9 m |
| Linearity |
Depends
on probe, cable length, and calibration method |
| Linear
Measuring Range |
+/-
.040 in |
+/-
1 mm |
|
Computer
Equipment
|
| Computer |
Industrial
Rack Mount (call for Latest Specs), CD,
LAN |
| Operating
System |
WinXP Professional |
| RAM |
2G |
| Monitor |
19"
LCD |
| Printer |
Color
inkjet (Optional) |
|
Software
Features
|
| Roughness
Filtering |
0,
15, 50, 150, 500, 1500 CPR |
| Roundness
Assessment |
Least
Squares |
| Radial
Display Resolution |
25
µ in / Division |
| Datum
Axis Definition |
Diameter/Diameter
or Face/Diameter |
| Auto
Correction |
Axial
and Radial misalignment |
| Interrupted
Surfaces |
Yes,
with Auto or Manual settings |
| Inspection
Modes |
Timed,
Triggered, Encoded |
|
|
AccuScan
4-Probe Inspection System
|
|
Analog
/ Digital Converter
|
| A/D
Conversion |
16-bit |
| Sampling
Resolution |
0.48
µ in |
0.012
µ m |
|
Measuring
Probes
|
| Probe
Type |
TESA
Auto reversing bi-directional lever probe** |
| Number
of Probes |
Four |
| Cable
length |
7
ft (14 ft with extension) |
2
m (4 m with extension) |
| +/-2s
Repeatability*** |
4
µ in |
0.101
µ m |
| Accuracy*** |
+/-
6.3 µ in |
+/-
0.16 µ m |
| Measurement
Force |
0.36
oz |
10
grams |
| Spindle
Pretravel |
0.002
in |
0.05
mm |
| Measuring
Range |
+/-
0.012 in |
+/-
0.3 mm |
| Overtravel |
0.002
in |
0.05
mm |
| Contact
Point Diameter |
0.079
in |
2
mm |
|
Computer
Equipment
|
| Computer |
Industrial
Rack Mount (call for Latest Specs), CD, Floppy,
LAN |
| Operating
System |
WinXP Professional |
| RAM |
4G |
| Monitor |
21"
LCD |
| Printer |
Color
Laserjet |
|
Software
Features
|
| Roughness
Filtering |
0,
15, 50, 150, 500, 1500 CPR |
| Roundness
Assessment |
Least
Squares |
| Radial
Display Resolution |
10
µ in / Division |
| Datum
Axis Definition |
Diameter/Diameter
or Face/Diameter |
| Auto
Correction |
Axial
and Radial misalignment |
| Interrupted
Surfaces |
Yes,
with Auto or Manual settings |
| Inspection
Modes |
Timed,
Triggered, Encoded |
All specifications are for standard equipment in our
standard configuration. Contact us for information regarding
finer-resolution systems or special ordering requirements.
** Other probes available on request: Pencil LVDT or
Half Bridge, Laser, Capacitance. Measuring ranges up
to +/- 0.5in. Call for specifications.
***
Accuracy and repeatability are for ideal conditions.
Overall accuracy will be affected by the precision of
the axis of rotation of the measurement system and environmental
conditions at the measurement site.
|
|
11,000
lb System Rotary Table Specifications
|
| Radial
Accuracy |
5.0
µ in |
0.125
µm |
| Axial
Accuracy |
5.0
µ in |
0.125
µm |
| Coning |
1.0
µ in/in |
(0.025
µm/25mm) |
| Weight
Capacity |
11,000
lb |
5,000
Kg |
| Centering
Adjustment |
0.4
in |
10
mm |
| Tilt
Adjustment |
+/-
0.5 deg |
| Table
Diameter |
40
in |
1
m |
| Air
Supply Requirement |
80-90
psi, dry to 35F |
| Operating
Speed |
1
RPM / 2 RPM |
| Power
Requirements |
110
Volts @ 60Hz |
|